BACKING OFF CIRCUIT
“The process of obtaining a direct reading mutual conductance figure is simplified by the introduction of a backing off circuit, which balances out the deflection due to the standing anode current at the desired test conditions prior to the measurement of mutual conductance. It will be noticed that the current flowing in this backing off circuit is similar in wave form, but precisely opposite in phase to the anode current, this eliminating any undesirable ripple that could otherwise become apparent when the meter, after backing off, was set to a sensitive range.” [from the original AVO MKIV working instructions]
AVO MK IV ENGLISH ILLUSTRATED MANUAL
(Available on request)
For explanatory purposes I re-printed the original owner’s manual, adding into it 22 new color pictures regarding the testing procedures. This one is available on request, togheter with the Service manual and the original Valve Data.
IL CIRCUITO BACKING OFF
“Il procedimento per poter ottenere la lettura diretta della mutua conduttanza è stato semplificato con l’introduzione del circuito <backing off> che esclude la deviazione dovuta alla crescente corrente anodica alle condizioni di prova desiderate prima della misurazione della mutua conduttanza. Deve essere notato che il flusso di corrente in questo circuito backing off è simile nella forma dell’onda, ma esattamente opposto come fase alla corrente dell’anodo, il che elimina ogni ondulazione indesiderabile che potrebbe apparire quando il meter, dopo il recedimento, è stato regolato su una gamma sensibile.” [dal manuale di istruzioni originale AVO MKIV]
AVO MK IV MANUALE ILLUSTRATO IN ITALIANO
(Disponibile a richiesta)
Ho tradotto in italiano sia il manuale di utilizzo e che quello di servizio, inserendo nel primo 22 nuove illustrazioni a scopo esplicativo delle procedure. Entrambi sono disponibili a richiesta, unitamente ai dati sulle valvole [Valve Data].
The Valve Panel, located in the upper side of the unit, comprises 17 valve holders of the following types :—English 4/5 pin. 7 and 9 pin. 8 pin side contact, B7G, B8A, B8B. (or B8G) (American Loctal), B9A, B9G, Mazda Octal, B3G. American 4, 5, 6 and small 7 pin UX, medium 7 pin UX and Octal. Morevoer, facilities have been provided to enable “flying lead” valves to be tested. Provision is made by means of plug-in adaptors to cater for newly introduced valve bases. The valve holders are all wired with their corresponding pins, according to the standard pin numbering, in parallel. i.e., all pins number one are wired together, all pins number, two, and so on. This wiring combination is associated with the well-known “AVO” Multi-Way Selector Switch which enables any one of the nine standard pin numbers to be connected to any one of the electrode test circuits in the Valve Characteristic Meter; thus, enabling any electrode combination to be set up for any normal valve holder.
Documents at your disposal
- The original AVO MKIV working instruction manual
- The original AVO MKIV service instruction manual
- The AVO MKIV working instruction with 21 new colour pictures, explaining all testing procedures
- The VALVE DATA (13.th Ed.) – high definition
Il Pannello delle valvole
Il pannello delle valvole contiene 17 supporti per valvole dei seguenti tipi: – English 4/5 pin, 7 e 9 pin, 8 pin contatto laterale (side contact), B7G, B8A, B8B. (o B8G) (American Loctal ), B9A, B9G, Mazda octal, B3G,American 4, 5, 6 pin, small 7 pin UX, medium 7 pin UX e octal. Inoltre, sono stati inseriti degli ausili per permettere l’esame di valvole “flying lead”. Sono state anche aggiunte delle predisposizioni mediante adattatori di ingresso per nuove basi di valvola. I supporti per le valvole sono tutti collegati con i rispettivi pin, secondo la numerazione standard dei pin, vale a dire, tutti i perni numero uno sono collegati insieme in parallelo, così come tutti i perni numero due e via di seguito. Questa combinazione dei collegamenti è connessa con il ben noto selettore Multi-Senso “AVO„ che permette a uno qualunque dei nove numeri di perni standard di essere collegato a uno qualunque dei circuiti di prova dell’elettrodo del Valve Characteristic Meter; quindi, consentendo l’inserimento di una qualunque combinazione di elettrodi per ciascun normale supporto di valvola.
Sono disponibili a richiesta:
- Il manuale di istruzioni AVO MKIV originale
- Il manuale di servizio originale AVO MKIV
- Il manuale di istruzioni in italiano con 21 nuove foto a colori a scopo esemplificativo delle procedure
- Il VALVE DATA ufficiale (13.ma edizione) ad alta definizione
Avo MKIV English illustrated manual
Avo MKIV manuale illustrato in italiano
In the following pictures some examples of testing procedures as indicated in my manual.
Le fotografie seguenti mostrano alcune delle procedure operative, così come illustrate nel mio manuale.